ꯗꯥꯏꯔꯦꯛꯇ-ꯑꯦꯛꯇꯤꯡ ꯁꯣꯂꯤꯅꯣꯏꯗ ꯚꯜꯌꯨꯁꯤꯡꯒꯤ ꯋꯥꯔꯀꯤꯡ ꯄ꯭ꯔꯤꯟꯁꯤꯄꯜ ꯑꯃꯁꯨꯡ ꯗꯥꯏꯔꯦꯛꯇ-ꯑꯦꯛꯇꯤꯡ ꯁꯣꯂꯤꯅꯣꯏꯗ ꯚꯜꯌꯨꯁꯤꯡꯒꯤ ꯁ꯭ꯠꯔꯀꯆꯔꯦꯜ ꯀꯝꯄꯣꯖꯤꯁꯟ ꯗꯥꯏꯑꯦꯒ꯭ꯔꯥꯐ꯫

Aug 13, 2025

ꯄꯥꯎꯖꯦꯜ ꯑꯃꯥ ꯊꯥꯗꯣꯀꯎ

ꯗꯥꯏꯔꯦꯛꯇ-ꯑꯦꯛꯇꯤꯡꯒꯤ ꯐꯉ꯭ꯀꯁꯟ꯫ꯁꯣꯂꯤꯅꯣꯏꯗ ꯚꯜꯌꯨꯁꯤꯡ ꯂꯩ꯫

ꯗꯥꯏꯔꯦꯛꯇ-ꯑꯦꯛꯇꯤꯡ ꯁꯣꯂꯤꯅꯣꯏꯗ ꯚꯜꯌꯨꯁꯤꯡ ꯑꯁꯤ ꯑꯄꯤꯀꯄꯥ-ꯗꯥꯏꯃꯦꯠꯔꯤꯛ ꯑꯃꯁꯨꯡ ꯂꯣ-ꯄ꯭ꯔꯦꯁꯔ ꯐ꯭ꯂꯨꯏꯗ ꯃꯤꯗꯤꯌꯥꯒꯤꯗꯃꯛ ꯁꯤꯖꯤꯟꯅꯩ꯫ ꯗꯥꯏꯔꯦꯛꯇ-ꯑꯦꯛꯇꯤꯡ ꯁꯣꯂꯤꯅꯣꯏꯗ ꯚꯜꯌꯨ ꯑꯗꯨ ꯍꯥꯡꯗꯣꯀꯄꯥ ꯃꯇꯃꯗꯥ, ꯃꯁꯤꯅꯥ ꯃꯦꯗꯤꯌꯝ ꯑꯗꯨꯒꯤ ꯑꯣꯄꯅꯤꯡ ꯄ꯭ꯔꯦꯁꯔ ꯑꯗꯨ ꯃꯊꯧ ꯇꯥꯗꯦ ꯑꯃꯁꯨꯡ ꯖꯤꯔꯣ ꯄ꯭ꯔꯦꯁꯔꯗꯒꯤ ꯍꯧꯕꯥ ꯌꯥꯏ꯫ ꯃꯁꯤꯒꯤ ꯁꯔꯚꯤꯁ ꯂꯥꯏꯐ ꯍꯦꯅꯒꯠꯍꯟꯅꯕꯒꯤꯗꯃꯛ, ꯃꯁꯤ ꯍꯣꯔꯥꯏꯖꯣꯟꯇꯦꯜ ꯄꯥꯏꯄꯂꯥꯏꯟ ꯔꯤꯡ ꯑꯗꯨ ꯃꯊꯛꯇꯥ ꯌꯦꯡꯗꯨꯅꯥ ꯏꯅꯁ꯭ꯇꯣꯜ ꯇꯧꯅꯕꯥ ꯄꯥꯎꯇꯥꯛ ꯄꯤꯔꯤ꯫ ꯗꯥꯏꯔꯦꯛꯇ-ꯑꯦꯛꯇꯤꯡ ꯁꯣꯂꯤꯅꯣꯏꯗ ꯚꯜꯌꯨꯁꯤꯡꯗꯥ ꯑꯄꯤꯀꯄꯥ ꯁꯥꯏꯖ, ꯑꯆꯧꯕꯥ ꯐ꯭ꯂꯣ ꯔꯦꯠ, ꯑꯃꯁꯨꯡ ꯌꯥꯝꯅꯥ ꯊꯨꯅꯥ ꯔꯦꯁ꯭ꯄꯣꯟꯁ ꯁ꯭ꯄꯤꯗ ꯌꯥꯑꯣꯏ꯫ ꯃꯈꯣꯌ ꯑꯁꯤ ꯑꯋꯥꯡꯕꯥ ꯑꯣꯄꯅꯤꯡ ꯑꯃꯁꯨꯡ ꯀ꯭ꯂꯣꯖꯤꯡ ꯐ꯭ꯔꯤꯛꯕꯦꯟꯁꯤ ꯂꯩꯕꯥ ꯅꯠꯠꯔꯒꯥ ꯌꯥꯝꯅꯥ ꯊꯨꯅꯥ ꯊꯤꯡꯖꯤꯅꯕꯥ ꯃꯊꯧ ꯇꯥꯕꯥ ꯑꯦꯞꯂꯤꯀꯦꯁꯅꯁꯤꯡꯒꯤꯗꯃꯛꯇꯥ ꯆꯨꯝꯃꯤ꯫ ꯄꯨꯝꯅꯃꯛ ꯑꯁꯤ ꯃꯔꯨꯑꯣꯏꯅꯥ ꯗꯥꯏꯔꯦꯛꯇ-ꯑꯦꯛꯇꯤꯡ ꯁꯣꯂꯤꯅꯣꯏꯗ ꯚꯜꯌꯨꯁꯤꯡ ꯈꯅꯕꯒꯤꯗꯃꯛ ꯆꯨꯝꯃꯤ꯫

The working principle of direct-acting solenoid valves and the structural composition diagram of direct-acting solenoid valves

ꯗꯥꯏꯔꯦꯛꯇ-ꯑꯦꯛꯇꯤꯡ ꯁꯣꯂꯤꯅꯣꯏꯗ ꯚꯜꯌꯨꯁꯤꯡꯒꯤ ꯋꯥꯔꯀꯤꯡ ꯄ꯭ꯔꯤꯟꯁꯤꯄꯜ꯫

ꯗꯥꯏꯔꯦꯛꯇ-ꯑꯦꯛꯇꯤꯡ ꯁꯣꯂꯤꯅꯣꯏꯗ ꯚꯜꯌꯨ: ꯄꯥꯋꯔ ꯑꯣꯟꯊꯣꯀꯄꯥ ꯃꯇꯃꯗꯥ, ꯏꯂꯦꯛꯠꯔꯣꯃꯦꯒ꯭ꯅꯦꯇꯤꯛ ꯀꯣꯏꯜ ꯑꯗꯨꯅꯥ ꯚꯜꯌꯨꯝ ꯁꯤꯠ ꯑꯗꯨꯗꯒꯤ ꯁꯤꯜ ꯑꯗꯨ ꯂꯧꯊꯣꯛꯅꯕꯥ ꯏꯂꯦꯛꯠꯔꯣꯃꯦꯒ꯭ꯅꯦꯇꯤꯛ ꯐꯣꯔꯁ ꯊꯣꯀꯍꯜꯂꯤ, ꯃꯗꯨꯅꯥ ꯚꯜꯌꯨ ꯑꯗꯨ ꯍꯥꯡꯗꯣꯀꯏ꯫ ꯄꯥꯋꯔ ꯑꯗꯨ ꯀꯀꯊꯠꯂꯕꯥ ꯃꯇꯃꯗꯥ, ꯏꯂꯦꯛꯠꯔꯣꯃꯦꯒ꯭ꯅꯦꯇꯤꯛ ꯐꯣꯔꯁ ꯑꯗꯨ ꯃꯥꯡꯈꯤ, ꯑꯃꯁꯨꯡ ꯁ꯭ꯞꯔꯤꯡ ꯑꯗꯨꯅꯥ ꯁꯤꯜ ꯑꯗꯨ ꯚꯜꯌꯨꯝ ꯁꯤꯠ ꯑꯗꯨꯗꯥ ꯆꯦꯟꯊꯈꯤꯗꯨꯅꯥ ꯚꯜꯌꯨ ꯑꯗꯨ ꯊꯤꯡꯖꯤꯜꯂꯤ꯫

ꯅꯣꯔꯃꯦꯜ ꯑꯣꯏꯅꯥ ꯀ꯭ꯂꯣꯖ ꯇꯧꯔꯕꯥ ꯗꯥꯏꯔꯦꯛꯇ-ꯑꯦꯛꯇꯤꯡ ꯁꯣꯂꯤꯅꯣꯏꯗ ꯚꯜꯌꯨ: ꯄꯥꯋꯔ ꯑꯣꯟꯊꯣꯀꯄꯥ ꯃꯇꯃꯗꯥ, ꯏꯂꯦꯛꯠꯔꯣꯃꯦꯒ꯭ꯅꯦꯇꯤꯛ ꯀꯣꯏꯜ ꯑꯁꯤꯅꯥ ꯆꯠꯂꯤꯕꯥ ꯁꯔꯨꯀꯁꯤꯡ (ꯚꯜꯌꯨ ꯁ꯭ꯇꯦꯝ, ꯚꯜꯌꯨ ꯀꯣꯔ, ꯁꯤꯂꯤꯡ ꯄꯥꯔꯇꯁꯤꯡ) ꯑꯗꯨ ꯚꯜꯌꯨꯒꯤ ꯁꯤꯠꯇꯒꯤ ꯂꯧꯊꯣꯛꯅꯕꯥ ꯃꯇꯤꯛ ꯆꯥꯕꯥ ꯏꯂꯦꯛꯠꯔꯣꯃꯦꯒ꯭ꯅꯦꯇꯤꯛ ꯐꯣꯔꯁ ꯊꯣꯀꯍꯜꯂꯤ, ꯑꯃꯁꯨꯡ ꯚꯜꯌꯨ ꯑꯗꯨ ꯍꯥꯡꯗꯣꯀꯏ꯫ ꯄꯥꯋꯔ ꯑꯗꯨ ꯀꯀꯊꯠꯂꯕꯥ ꯃꯇꯃꯗꯥ, ꯁ꯭ꯞꯔꯤꯡ ꯐꯣꯔꯁꯅꯥ ꯆꯠꯊꯣꯛ-ꯆꯠꯁꯤꯟ ꯇꯧꯔꯤꯕꯥ ꯁꯔꯨꯀꯁꯤꯡ ꯑꯗꯨ ꯚꯜꯌꯨꯝ ꯁꯤꯠ ꯑꯗꯨꯗꯥ ꯆꯦꯠꯅꯥ ꯊꯃꯖꯤꯜꯂꯤ, ꯑꯃꯁꯨꯡ ꯚꯜꯌꯨ ꯑꯗꯨ ꯊꯤꯡꯖꯤꯜꯂꯤ꯫

ꯅꯣꯔꯃꯦꯜ ꯑꯣꯏꯅꯥ ꯑꯣꯄꯟ ꯗꯥꯏꯔꯦꯛꯇ-ꯑꯦꯛꯇꯤꯡ ꯁꯣꯂꯤꯅꯣꯏꯗ ꯚꯜꯌꯨ: ꯑꯦꯛꯁꯅꯒꯤ ꯃꯥꯌꯀꯩ ꯑꯁꯤ ꯅꯣꯔꯃꯦꯜ ꯑꯣꯏꯅꯥ ꯀ꯭ꯂꯣꯖ ꯇꯧꯔꯕꯥ ꯃꯈꯂꯒꯤ ꯑꯗꯨꯒꯥ ꯃꯥꯟꯅꯗꯦ꯫

 

ꯗꯥꯏꯔꯦꯛꯇ-ꯑꯦꯛꯇꯤꯡ ꯁꯣꯂꯤꯅꯣꯏꯗ ꯚꯜꯌꯨꯒꯤ ꯁ꯭ꯠꯔꯀꯆꯔꯦꯜ ꯀꯝꯄꯣꯖꯤꯁꯟ ꯗꯥꯏꯑꯦꯒ꯭ꯔꯥꯐ꯫

ꯑꯄꯤꯀꯄꯥ-ꯗꯥꯏꯃꯦꯠꯔꯤꯛ ꯗꯥꯏꯔꯦꯛꯇ-ꯑꯦꯛꯇꯤꯡ ꯁꯣꯂꯤꯅꯣꯏꯗ ꯚꯜꯌꯨ (ꯐꯤꯒꯔ 1)ꯒꯤ ꯅꯣꯃꯤꯅꯦꯜ ꯁꯥꯏꯖ ꯑꯁꯤ DN10ꯗꯒꯤ ꯍꯦꯜꯂꯣꯏ꯫ ꯆꯠꯊꯔꯤꯕꯥ ꯑꯥꯏꯔꯟ ꯀꯣꯔꯒꯤ ꯃꯈꯥ ꯊꯪꯕꯥ ꯁꯔꯨꯛ ꯑꯗꯨ ꯁꯤꯂꯤꯡ ꯄ꯭ꯂꯒ ꯑꯃꯅꯥ ꯌꯥꯎꯏ꯫ ꯆꯠꯊꯔꯤꯕꯥ ꯑꯥꯏꯔꯟ ꯀꯣꯔꯒꯤ ꯃꯊꯛꯇꯥ ꯑꯃꯁꯨꯡ ꯃꯈꯥꯗꯥ ꯆꯠꯊꯣꯛ-ꯆꯠꯁꯤꯟ ꯇꯧꯕꯅꯥ ꯁꯣꯂꯤꯅꯣꯏꯗ ꯚꯜꯌꯨꯒꯤ ꯋꯥꯔꯀꯤꯡ ꯃꯦꯗꯤꯌꯃꯒꯤ ꯑꯣꯟ-ꯑꯣꯐ ꯀꯟꯠꯔꯣꯜ ꯐꯪꯍꯅꯕꯥ ꯉꯝꯃꯤ, ꯃꯔꯝ ꯑꯗꯨꯅꯥ ꯃꯁꯤꯕꯨ ꯗꯥꯏꯔꯦꯛꯇ-ꯑꯦꯛꯇꯤꯡ ꯁꯣꯂꯤꯅꯣꯏꯗ ꯚꯜꯌꯨ ꯍꯥꯌꯅꯥ ꯀꯧꯏ꯫

 

Small-diameter direct-acting solenoid valve

ꯐꯤꯒꯔ 1: ꯑꯄꯤꯀꯄꯥ-ꯗꯥꯏꯃꯦꯠꯔꯤꯛ ꯗꯥꯏꯔꯦꯛꯇ-ꯑꯦꯛꯇꯤꯡ ꯁꯣꯂꯤꯅꯣꯏꯗ ꯚꯜꯌꯨ꯫

1 - ꯚꯜꯌꯨꯒꯤ ꯍꯀꯆꯥꯡ; 2 - ꯊꯥꯒꯤ ꯈꯣꯡꯆꯠ; 3 - ꯚꯜꯌꯨ ꯀꯚꯔ; 4 - ꯆꯠꯊꯣꯛ-ꯆꯠꯁꯤꯟ ꯇꯧꯕꯥ ꯑꯥꯏꯔꯟ ꯀꯣꯔ; 5 - ꯀꯣꯏꯜ; 6 - ꯁ꯭ꯇꯦꯇꯤꯛ ꯑꯥꯏꯔꯟ ꯀꯣꯔ꯫

 

ꯗꯥꯏꯔꯦꯛꯇ-ꯑꯦꯛꯇꯤꯡ ꯕꯥꯏꯗꯥꯏꯔꯦꯛꯁꯅꯦꯜ ꯁꯣꯂꯤꯅꯣꯏꯗ ꯚꯜꯌꯨ ꯃꯈꯜ ꯑꯁꯤꯒꯤ ꯁꯣꯂꯤꯅꯣꯏꯗ ꯚꯜꯌꯨ ꯑꯁꯤ ꯗꯤꯖꯥꯏꯅꯗꯥ ꯑꯍꯣꯡꯕꯥ ꯑꯃꯁꯨꯡ ꯄꯔꯐꯣꯃꯦꯟꯁꯇꯥ ꯊꯥꯖꯕꯥ ꯌꯥꯕꯥ ꯑꯣꯏ꯫ ꯃꯁꯤꯒꯤ ꯋꯥꯔꯀꯤꯡ ꯄ꯭ꯔꯦꯁꯔ ꯑꯁꯤ 0 (ꯄ꯭ꯔꯦꯁꯔꯒꯤ ꯈꯦꯠꯅꯕꯥ ꯂꯩꯇꯕꯥ)ꯗꯒꯤ 4.0MPa ꯐꯥꯎꯕꯥ ꯑꯣꯏꯕꯥ ꯌꯥꯏ, ꯑꯃꯁꯨꯡ ꯃꯁꯤ ꯃꯔꯨꯑꯣꯏꯅꯥ 1.33×10-7 mpaꯗꯒꯤ ꯍꯦꯟꯅꯥ ꯅꯦꯝꯕꯥ ꯅꯠꯠꯔꯒꯥ ꯃꯥꯟꯅꯕꯥ ꯄ꯭ꯔꯦꯁꯔ ꯂꯩꯕꯥ ꯚꯦꯛꯌꯨꯝ ꯁꯤꯁ꯭ꯇꯦꯃꯁꯤꯡꯒꯤꯗꯃꯛꯇꯥ ꯆꯨꯝꯃꯤ꯫ ꯃꯁꯤꯒꯤ ꯚꯜꯌꯨ ꯑꯁꯤꯅꯥ ꯃꯃꯥꯡ ꯑꯃꯁꯨꯡ ꯃꯇꯨꯡꯒꯤ ꯃꯥꯌꯀꯩ ꯑꯅꯤꯃꯛꯇꯥ (ꯃꯥꯏꯀꯩ ꯑꯅꯤꯃꯛꯇꯥ ꯁꯤꯂꯤꯡꯒꯥ ꯂꯣꯌꯅꯅꯥ) ꯃꯦꯗꯤꯌꯃꯒꯤ ꯐ꯭ꯂꯣ ꯑꯗꯨ ꯐꯪꯕꯥ ꯉꯝꯃꯤ꯫

 

Direct-acting bidirectional solenoid valve

ꯐꯤꯒꯔ 2 ꯗꯥꯏꯔꯦꯛꯇ-ꯑꯦꯛꯇꯤꯡ ꯕꯥꯏꯗꯔꯥꯏꯖꯦꯁꯅꯦꯜ ꯁꯣꯂꯤꯅꯣꯏꯗ ꯚꯜꯌꯨ꯫

1 - ꯏꯂꯦꯛꯠꯔꯣꯃꯦꯒ꯭ꯅꯦꯇꯤꯛ ꯍꯦꯗ; 2 - ꯆꯠꯊꯣꯛ-ꯆꯠꯁꯤꯟ ꯇꯧꯕꯥ ꯑꯥꯏꯔꯟ ꯀꯣꯔ; 3 - ꯚꯜꯌꯨ ꯁ꯭ꯇꯦꯝ ꯑꯦꯁꯦꯝꯕꯂꯤ; 4 - ꯚꯜꯌꯨ ꯁꯤꯠ; 5 - ꯚꯜꯌꯨ ꯕꯣꯗꯤ꯫

ꯑꯄꯤꯀꯄꯥ ꯗꯥꯏꯑꯦꯃꯤꯇꯔ ꯂꯩꯕꯥ ꯗꯥꯏꯔꯦꯛꯇ-ꯑꯦꯛꯇꯤꯡ ꯊ꯭ꯔꯤ-ꯋꯦ ꯁꯣꯂꯤꯅꯣꯏꯗ ꯚꯜꯌꯨꯁꯤꯡ (ꯐꯤꯒꯔ 3) ꯑꯁꯤ ꯆꯥꯏꯅꯥꯗꯥ ꯌꯥꯝꯅꯥ ꯀꯃꯟ ꯑꯣꯏ, ꯃꯍꯧꯁꯥꯅꯥ 0ꯗꯒꯤ 1.0MPa ꯐꯥꯎꯕꯥ ꯑꯣꯏ꯫ DN3ꯗꯒꯤ ꯍꯦꯟꯅꯥ ꯅꯦꯝꯕꯥ ꯅꯠꯠꯔꯒꯥ ꯃꯥꯟꯅꯕꯥ ꯗꯥꯏꯑꯦꯃꯤꯇꯔ ꯂꯩꯕꯥ ꯗꯥꯏꯔꯦꯛꯇ-ꯑꯦꯛꯇꯤꯡ ꯁꯣꯂꯤꯅꯣꯏꯗ ꯚꯜꯌꯨꯁꯤꯡ ꯑꯁꯤ ꯌꯨꯃꯗꯥ ꯑꯃꯁꯨꯡ ꯃꯄꯥꯟꯗꯥ ꯄꯥꯛ-ꯁꯟꯅꯥ ꯁꯤꯖꯤꯟꯅꯩ, ꯑꯌꯥꯝꯕꯅꯥ ꯃꯜꯇꯤ-ꯋꯦ ꯅ꯭ꯌꯨꯃꯦꯇꯤꯛ ꯁꯣꯂꯤꯅꯣꯏꯗ ꯚꯜꯌꯨꯁꯤꯡꯒꯤꯗꯃꯛꯇꯥ ꯄꯥꯏꯂꯣꯠ ꯚꯜꯌꯨ ꯑꯣꯏꯅꯥ ꯊꯕꯛ ꯇꯧꯏ꯫

 

Direct-acting three-way solenoid valve

ꯐꯤꯒꯔ 3 ꯗꯥꯏꯔꯦꯛꯇ-ꯑꯦꯛꯇꯤꯡ ꯊ꯭ꯔꯤ-ꯋꯦ ꯁꯣꯂꯤꯅꯣꯏꯗ ꯚꯜꯌꯨ꯫

 

ꯑꯗꯨꯝ ꯑꯣꯏꯅꯃꯛ, DN12ꯗꯒꯤ 50 ꯐꯥꯎꯕꯒꯤ ꯗꯥꯏꯑꯦꯃꯤꯇꯔ ꯂꯩꯕꯥ ꯑꯆꯧꯕꯥ-ꯗꯥꯏꯃꯦꯠꯔꯤꯛ ꯊ꯭ꯔꯤ-ꯋꯦ, ꯐꯣꯔ-ꯋꯦ (ꯃꯉꯥ-ꯋꯦ) ꯁꯣꯂꯤꯅꯣꯏꯗ ꯚꯜꯌꯨꯁꯤꯡꯒꯤ ꯑꯣꯏꯅꯗꯤ, ꯃꯃꯥꯡꯗꯥ ꯆꯥꯏꯅꯥꯗꯥ ꯃꯇꯝ ꯄꯨꯝꯅꯃꯛꯇꯥ ꯒꯦꯞ ꯑꯃꯥ ꯂꯩꯔꯝꯃꯤ꯫ ꯖꯔꯃꯅꯤꯒꯤ ꯍꯦꯔꯤ-ꯑꯣꯟ ꯀꯝꯄꯦꯅꯤꯒꯤ ꯃꯦꯟꯌꯨꯐꯦꯀꯆꯔꯤꯡ ꯇꯦꯛꯅꯣꯂꯣꯖꯤ ꯑꯁꯤ ꯆꯥꯏꯅꯥꯗꯥ ꯁꯤꯖꯤꯟꯅꯔꯕꯥ ꯃꯇꯨꯡꯗꯥ, ꯗꯥꯏꯖꯦꯁꯟ ꯑꯃꯁꯨꯡ ꯑꯦꯕꯁꯣꯔꯄꯁꯅꯒꯤ ꯈꯨꯠꯊꯥꯡꯗꯥ, ꯗꯣꯃꯦꯁ꯭ꯇꯤꯛ ꯄ꯭ꯔꯗꯛꯁꯟ ꯐꯪꯂꯦ꯫ ꯃꯁꯤ ꯑꯦꯛꯇꯤꯕꯦꯇꯔꯁꯤꯡꯒꯤꯗꯃꯛꯇꯥ ꯃꯜꯇꯤ-ꯋꯦ ꯁꯣꯂꯤꯅꯣꯏꯗ ꯚꯜꯌꯨ ꯑꯃꯥ ꯑꯣꯏꯅꯥ ꯁꯤꯖꯤꯟꯅꯕꯇꯥ ꯅꯠꯇꯅꯥ ꯍꯥꯏꯗ꯭ꯔꯣꯂꯤꯛ ꯑꯃꯁꯨꯡ ꯅ꯭ꯌꯨꯃꯦꯇꯤꯛ ꯑꯦꯛꯇꯤꯕꯦꯇꯔꯁꯤꯡꯗꯁꯨ ꯐꯪꯏ꯫

ꯗꯥꯏꯔꯦꯛꯇ-ꯑꯦꯛꯇꯤꯡ ꯇꯨ-ꯄꯣꯖꯤꯁꯟ ꯊ꯭ꯔꯤ-ꯋꯦ ꯁꯣꯂꯤꯅꯣꯏꯗ ꯚꯜꯌꯨ (ꯐꯤꯒꯔ 4) ꯑꯁꯤꯅꯥ ꯐꯉ꯭ꯀꯁꯟ ꯃꯔꯤ ꯐꯪꯕꯥ ꯉꯝꯃꯤ: ꯅꯣꯔꯃꯦꯜ ꯑꯣꯏꯅꯥ ꯊꯤꯡꯖꯤꯅꯕꯥ, ꯅꯣꯔꯃꯦꯜ ꯑꯣꯏꯅꯥ ꯍꯥꯡꯗꯣꯀꯄꯥ, ꯔꯤꯚꯔꯁ ꯇꯧꯕꯥ ꯑꯃꯁꯨꯡ ꯀꯅꯚꯔꯖꯤꯡ ꯇꯧꯕꯥ, ꯃꯁꯤꯒꯤ ꯀꯅꯦꯛꯇꯤꯡ ꯄꯥꯏꯄꯀꯤ ꯄꯣꯖꯤꯁꯅꯒꯤ ꯃꯇꯨꯡꯏꯟꯅꯥ꯫

ꯗꯥꯏꯔꯦꯛꯇ-ꯑꯦꯛꯇꯤꯡ ꯕꯥꯏꯗꯥꯏꯔꯦꯛꯁꯅꯦꯜ ꯁꯣꯂꯤꯅꯣꯏꯗ ꯚꯜꯌꯨ ꯃꯈꯜ ꯑꯁꯤꯒꯤ ꯁꯣꯂꯤꯅꯣꯏꯗ ꯚꯜꯌꯨ ꯑꯁꯤ ꯗꯤꯖꯥꯏꯅꯗꯥ ꯑꯍꯣꯡꯕꯥ ꯑꯃꯁꯨꯡ ꯄꯔꯐꯣꯃꯦꯟꯁꯇꯥ ꯊꯥꯖꯕꯥ ꯌꯥꯕꯥ ꯑꯣꯏ꯫ ꯃꯁꯤꯒꯤ ꯋꯥꯔꯀꯤꯡ ꯄ꯭ꯔꯦꯁꯔ ꯑꯁꯤ 0 (ꯄ꯭ꯔꯦꯁꯔꯒꯤ ꯈꯦꯠꯅꯕꯥ ꯂꯩꯇꯕꯥ)ꯗꯒꯤ 4.0MPa ꯐꯥꯎꯕꯥ ꯑꯣꯏꯕꯥ ꯌꯥꯏ, ꯑꯃꯁꯨꯡ ꯃꯁꯤ ꯃꯔꯨꯑꯣꯏꯅꯥ 1.33×10-7 mpaꯗꯒꯤ ꯍꯦꯟꯅꯥ ꯅꯦꯝꯕꯥ ꯅꯠꯠꯔꯒꯥ ꯃꯥꯟꯅꯕꯥ ꯄ꯭ꯔꯦꯁꯔ ꯂꯩꯕꯥ ꯚꯦꯛꯌꯨꯝ ꯁꯤꯁ꯭ꯇꯦꯃꯁꯤꯡꯒꯤꯗꯃꯛꯇꯥ ꯆꯨꯝꯃꯤ꯫ ꯃꯁꯤꯒꯤ ꯚꯜꯌꯨ ꯑꯁꯤꯅꯥ ꯃꯃꯥꯡ ꯑꯃꯁꯨꯡ ꯃꯇꯨꯡꯒꯤ ꯃꯥꯌꯀꯩ ꯑꯅꯤꯃꯛꯇꯥ (ꯃꯥꯏꯀꯩ ꯑꯅꯤꯃꯛꯇꯥ ꯁꯤꯂꯤꯡꯒꯥ ꯂꯣꯌꯅꯅꯥ) ꯃꯦꯗꯤꯌꯃꯒꯤ ꯐ꯭ꯂꯣ ꯑꯗꯨ ꯐꯪꯕꯥ ꯉꯝꯃꯤ꯫

 

Direct-acting two-position three-way solenoid valve

ꯐꯤꯒꯔ 4 ꯗꯥꯏꯔꯦꯛꯇ-ꯑꯦꯛꯇꯤꯡ ꯇꯨ-ꯄꯣꯖꯤꯁꯟ ꯊ꯭ꯔꯤ-ꯋꯦ ꯁꯣꯂꯤꯅꯣꯏꯗ ꯚꯜꯌꯨ꯫

1 - ꯚꯜꯌꯨꯒꯤ ꯍꯀꯆꯥꯡ; 2 - ꯚꯜꯌꯨ ꯁꯤꯠ; 3 - ꯚꯜꯌꯨ ꯁ꯭ꯇꯦꯝ ꯑꯦꯁꯦꯝꯕꯂꯤ; 4 - ꯆꯠꯊꯣꯛ-ꯆꯠꯁꯤꯟ ꯇꯧꯕꯥ ꯑꯥꯏꯔꯟ ꯀꯣꯔ; 5 - ꯏꯂꯦꯛꯠꯔꯣꯃꯦꯒ꯭ꯅꯦꯇꯤꯛ ꯍꯦꯗ꯫

ꯗꯥꯏꯔꯦꯛꯇ-ꯑꯦꯛꯇꯤꯡ ꯇꯨ-ꯄꯣꯖꯤꯁꯟ ꯐꯣꯔ-ꯋꯦ ꯁꯣꯂꯤꯅꯣꯏꯗ ꯚꯜꯌꯨ (ꯐꯤꯒꯔ 5) ꯑꯃꯁꯨꯡ ꯇꯨ{4}}ꯄꯣꯖꯤꯁꯟ ꯐꯥꯏꯚ-ꯋꯦ ꯁꯣꯂꯤꯅꯣꯏꯗ ꯚꯜꯌꯨꯒꯤ ꯏꯅꯂꯦꯠ ꯗꯤꯔꯦꯛꯁꯟ ꯑꯃꯁꯨꯡ ꯋꯥꯔꯀꯤꯡ ꯄꯣꯔꯠ ꯗꯤꯔꯦꯛꯁꯟ (ꯅꯣꯔꯃꯦꯜ ꯑꯣꯏꯅꯥ ꯑꯣꯄꯟ ꯑꯃꯁꯨꯡ ꯅꯣꯔꯃꯦꯜ ꯑꯣꯏꯅꯥ ꯀ꯭ꯂꯣꯖꯗ) ꯑꯁꯤ ꯐꯤꯛꯁ ꯇꯧꯏ꯫ ꯃꯈꯣꯌꯒꯤ ꯃꯅꯨꯡꯗꯥ, ꯗꯥꯏꯔꯦꯛꯇ-ꯑꯦꯛꯇꯤꯡ ꯇꯨ-ꯄꯣꯖꯤꯁꯟ ꯐꯣꯔ-ꯋꯦ ꯁꯣꯂꯤꯅꯣꯏꯗ ꯚꯜꯌꯨ ꯑꯁꯤꯅꯥ "A" ꯑꯃꯁꯨꯡ "B" ꯋꯥꯔꯀꯤꯡ ꯄꯣꯔꯇꯁꯤꯡꯒꯤ ꯑꯦꯒꯖꯁ꯭ꯠ ꯄꯣꯔꯇꯁꯤꯡ ꯑꯁꯤ ꯑꯃꯗꯥ ꯄꯨꯅꯁꯤꯟꯗꯨꯅꯥ ꯗꯥꯏꯔꯦꯛꯇ-ꯑꯦꯛꯇꯤꯡ ꯇꯨ-ꯄꯣꯖꯤꯁꯟ ꯐꯣꯔ-ꯋꯦ ꯁꯣꯂꯤꯅꯣꯏꯗ ꯚꯜꯌꯨ ꯑꯃꯥ ꯁꯦꯝꯃꯤ꯫

 

Direct-acting two-position four-way two-position five-way solenoid valve

ꯐꯤꯒꯔ 5 ꯗꯥꯏꯔꯦꯛꯇ-ꯑꯦꯛꯇꯤꯡ ꯑꯅꯤ-ꯄꯣꯖꯤꯁꯟ ꯃꯔꯤ-ꯋꯦ (ꯑꯅꯤ-ꯄꯣꯖꯤꯁꯟ ꯃꯉꯥ-ꯋꯦ) ꯁꯣꯂꯤꯅꯣꯏꯗ ꯚꯜꯌꯨ꯫

1 - ꯚꯜꯌꯨꯒꯤ ꯍꯀꯆꯥꯡ; 2 - ꯚꯜꯌꯨ ꯁꯤꯠ; 3 - ꯚꯜꯌꯨ ꯁ꯭ꯇꯦꯝ ꯑꯦꯁꯦꯝꯕꯂꯤ; 4 - ꯁꯤꯂꯤꯡ ꯔꯤꯡ; 5 - ꯆꯠꯊꯣꯛ-ꯆꯠꯁꯤꯟ ꯇꯧꯕꯥ ꯑꯥꯏꯔꯟ ꯀꯣꯔ; 6 - ꯁ꯭ꯞꯔꯤꯡ ꯔꯤꯁꯦꯠ ꯇꯧꯕꯥ; 7 - ꯏꯂꯦꯛꯠꯔꯣꯃꯦꯒ꯭ꯅꯦꯇꯤꯛ ꯍꯦꯗ꯫

ꯃꯊꯛꯇꯥ ꯄꯅꯈ꯭ꯔꯤꯕꯥ ꯑꯁꯤ ꯗꯥꯏꯔꯦꯛꯇ-ꯑꯦꯛꯇꯤꯡ ꯁꯣꯂꯤꯅꯣꯏꯗ ꯚꯜꯌꯨꯁꯤꯡꯒꯤ ꯋꯥꯔꯀꯤꯡ ꯄ꯭ꯔꯤꯟꯁꯤꯄꯜ ꯑꯃꯁꯨꯡ ꯗꯥꯏꯔꯦꯛꯇ-ꯑꯦꯛꯇꯤꯡ ꯁꯣꯂꯤꯅꯣꯏꯗ ꯚꯜꯌꯨꯁꯤꯡꯒꯤ ꯀꯟꯇꯦꯟꯇꯀꯤ ꯁ꯭ꯠꯔꯀꯆꯔꯦꯜ ꯀꯝꯄꯣꯖꯤꯁꯟ ꯗꯥꯏꯑꯦꯒ꯭ꯔꯥꯐ, ꯍꯦꯟꯅꯥ ꯃꯔꯤ ꯂꯩꯅꯕꯥ ꯏꯅꯐꯣꯔꯃꯦꯁꯟ ꯈꯪꯅꯕꯒꯤꯗꯃꯛꯇꯥ ꯐꯪꯒꯅꯤ꯫https://www.joosungauto.com/ ꯗꯥ ꯊꯥꯕꯤꯔꯀꯎ꯫

ꯏꯅꯛꯕꯥꯔꯤ ꯊꯥꯕꯤꯌꯨ